112
•
Appendix E: Three Letter Commands
Notes
Returns a snap shot of the camera’s settings
e.g.
OK>gcp
*** Camera Settings ***
Manufacturer Name:Teledyne DALSA
Model Name: FA_81_8M100_01
Family Name: Falcon2
Sensor Type: Bayer Color Filter Array
Device Version: 255.101.591
Manufacturer Info:
Serial Number: C123456
User Defined Name:myCamera
Device Firmware 03-081-20261-06BETA
FPGA Info: Rev:46(8-4-2013 16:47)
Calibration Date: 0
CPU Temp.: 39 [C]
Sensor Temp.: 45 [C]
Default Set: User Set 1
Frame Rate: NA [Hz]
Exposure Time: NA [us]
Exposure Mode: TriggerWidth
System Gain: 1.00
Red Gain: 1.00
Green Red Gain: 1.00
Blue Gain: 1.00
Green Blue Gain: 1.00
An. Coarse Gain: 2
Analog Offset: 0
Backgd Subtract: 0
Aspect Ratio: 4 to 3
Sensor Bit Depth: 8 [bpp]
Test Image: FPN Diagonal Ramp
Test Static Value:0
CameraLink Taps: 10 [taps]
Serial Baud Rate: 460800
AOI(x,y,w,h): (0, 0, 3328, 2502)
Trigger Mode: External
Trigger Source: CC1
Trigger Delay: 0 [us]
** General Purpose Input Settings **
Input Threshold: 2.4 [V]
Name Debounce Inverter State
Line 1: 1 On 1
Line 2: 1 On 1
CC1: 1 On 0
CC2: 1 On 0
CC3: 1 On 0
CC4: 1 On 0
** General Purpose Output Settings **
Name Line Source Inverter State Delay(us) Duration(us) Sw.Latch Mode Sw Line Val
Line 3: Off On 1 0 1000 Off Inactive
Line 4: Off On 1 0 1000 Off Inactive
** Flatfield Settings **
FF Mode: Calibration
FF Set: Userset 1
FF Cur Gain Mode: High Gain
Содержание FA-80-12M1H-XX-R
Страница 1: ...Falcon2 Camera User s Manual 4M 8M and 12M Area Imaging P N 03 032 20107 04 www teledynedalsa com ...
Страница 14: ...14 The Falcon2 Cameras Figure 3 Quantum Efficiency INSERT QE GRAPH HERE ...
Страница 17: ...The Falcon2 Cameras 17 Mechanicals Figure 5 Camera Mechanical ADD MECHANICAL PDF HERE ...
Страница 53: ...Camera Operation 53 Figure 19 Advanced Processing Control ...