Appendix E: Three Letter Commands
•
109
Full Name
calibrate pixel replacement
Mnemonic
cpr
Argument(s)
threshold
Specifies the difference between offset(FPN) and average
value(during pixel calibration), above which the pixel is marked as
defective.
GenICam
flatfieldCalibrationPixelReplacement
flatfieldCalibrationPixelReplacementOffsetThreshold
Release
6
Notes
Only available when flat field mode is set to calibration ( i.e. ffm = CAL)
May take several seconds to several minutes to complete depending on frame rate
See Appendix D: Internal Flat Field Calibration Algorithms for more information.
Full Name
flatfield clear coefficients
Mnemonic
fcc
GenICam
flatfieldCalibrationClearCoefficient
Release
6
Notes
Only available when flat field mode is set to calibration ( i.e. ffm = CAL)
Clears the current set selected by the
fsc
command
Full Name
flatfield copy from
Mnemonic
fcf
Argument(s)
source
F: Copy from factory set
1: Copy from set 1
2: Copy from set 2
3: Copy from set 3
4: Copy from set 4
GenICam
flatfieldCoefficientsCopyInCurrent
Release
6
Notes
Only available when flat field mode is set to calibration ( i.e. ffm = CAL)
There is a factory flat field set for every input pixel size.
Full Name
flatfield set current F|1|2|3|4
Mnemonic
fsc
Argument(s)
current set
F: Set current to factory set
1: Set current to set 1
2: Set current to set 2
3: Set current to set 3
4: Set current to set 4
GenICam
flatfieldCorrectionCurrentActiveSet
Release
6
Notes
Only available when flat field mode is not set to calibration ( i.e. ffm != CAL)
Содержание FA-80-12M1H-XX-R
Страница 1: ...Falcon2 Camera User s Manual 4M 8M and 12M Area Imaging P N 03 032 20107 04 www teledynedalsa com ...
Страница 14: ...14 The Falcon2 Cameras Figure 3 Quantum Efficiency INSERT QE GRAPH HERE ...
Страница 17: ...The Falcon2 Cameras 17 Mechanicals Figure 5 Camera Mechanical ADD MECHANICAL PDF HERE ...
Страница 53: ...Camera Operation 53 Figure 19 Advanced Processing Control ...