DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
408
create sflow counter_poller ports
Purpose
Used to create the sFlow counter poller. The poller function instructs
the Switch to forward statistics counter information with respect to a
port.
Syntax
create sflow counter_poller ports [<portlist> | all]
analyzer_server_id <int 1-4> {interval [disable | <sec 20-120>]}
Description
The
create sflow counter_poller ports
command is used to create
the sFlow counter poller.
Parameters
<portlist> | all –
Specify the list of ports or all ports to be configured.
analyzer_server_id <int 1-4> -
Specify the ID of an analyzer server.
This value must be between 1 and 4.
interval [disable | <sec 20-120>] –
The maximum number of seconds
between successive statistics counters information. Enter the
maximum number of seconds between successive statistics
counters information between 20 and 120 seconds. Or specify
disable which will not export counter until the interval to be set an
appropriate value.
Restrictions
Only Administrator, operator and power user-level users can issue
this command.
Example usage:
To create sFlow counter poller, which sample port 1 to analyzer server 1:
DGS-1210-28MP/ME:5# create sflow counter_poller ports 1 analyzer_server_id 1
Command: create sflow counter_poller ports 1 analyzer_server_id 1
Success.
DGS-1210-28MP/ME:5#
config sflow counter_poller ports
Purpose
Used to configure the sFlow counter poller. If the user wants the
change the analyzer_server_id, he needs to delete the
counter_poller and creates a new one.
Syntax
config sflow counter_poller ports [<portlist> | all] interval
[disable | <sec 20-120>]
Description
The
config sflow counter_poller ports
command is used to
configure the sFlow counter poller.
Parameters
<portlist> | all –
Specify the list of ports or all ports to be configured.
interval –
The maximum number of seconds between successive
samples of the counters.
[disable | <sec 20-120>] –
Specify disable to stop exporting counter.
Or enter the maximum number of seconds between successive
samples of the counters. This value must be between 20 and 120.
Restrictions
Only Administrator, operator and power user-level users can issue
this command.
Example usage:
Содержание DGS-1210/ME series
Страница 61: ...DGS 1210 ME Metro Ethernet Switch CLI Reference Guide 41 Sending mail please wait Success DGS 1210 28MP ME 5 ...
Страница 186: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 166 DGS 1210 28MP ME 5 ...
Страница 190: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 170 Success DGS 1210 28MP ME 5 ...
Страница 386: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 366 Port Max Group 1 v6 256 3 v6 256 DGS 1210 28MP ME 5 ...