DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
111
Description
The
config snmp system_ location
command is used to enter a
Description of the location of the Switch. A maximum of 20
characters can be used.
Parameters
<string 128>
−
A maximum of 128 characters is allowed. A NULL
string is accepted if there is no location desired.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To configure the Switch location to “
HQ
”:
DGS-1210-28MP/ME:5# config snmp system_location HQ
Command: config snmp system_location HQ
Success.
DGS-1210-28MP/ME:5#
config snmp system_name
Purpose
To configure the name of the location of the Switch.
Syntax
config snmp system_name <string 128>
Description
The
config snmp system_ name
command configures the name of
the Switch.
Parameters
<string 128>
−
A maximum of 128 characters is allowed. A NULL
string is accepted if there is no location Desired.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To configure the Switch name for “DGS-1210:
DGS-1210-28MP/ME:5# config snmp system_name DGS-1210
Command: config snmp system_name DGS-1210
Success.
DGS-1210-28MP/ME:5#
config snmp warmstart_traps
Purpose
To enable or disable the warm start traps of SNMPon the Switch.
Syntax
config snmp warmstart_traps [enable | disable]
Description
The
config snmp warmstart_traps
command enable or disable the
warm start traps of the Switch.
Parameters
[enable | disable] –
Enable or disable the warm start traps of the
Switch.
Restrictions
Only Administrator or operator-level users can issue this command.
Example usage:
To enable SNMP warm start traps for the Switch:
DGS-1210-28MP/ME:5# config snmp warmstart_traps enable
Содержание DGS-1210/ME series
Страница 61: ...DGS 1210 ME Metro Ethernet Switch CLI Reference Guide 41 Sending mail please wait Success DGS 1210 28MP ME 5 ...
Страница 186: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 166 DGS 1210 28MP ME 5 ...
Страница 190: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 170 Success DGS 1210 28MP ME 5 ...
Страница 386: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 366 Port Max Group 1 v6 256 3 v6 256 DGS 1210 28MP ME 5 ...