DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
387
DGS-1210-28MP/ME:5# config sntp primary 10.1.1.1 secondary 10.1.1.2 poll-interval
60
Command: config sntp primary 10.1.1.1 secondary 10.1.1.2 poll-interval 60
Success.
DGS-1210-28MP/ME:5#
show sntp
Purpose
To display the SNTP information.
Syntax
show sntp
Description
The
show sntp
command displays SNTP settings information,
including the source IP address, time source and poll interval.
Parameters
None.
Restrictions
None.
Example usage:
To display SNTP configuration information:
DGS-1210-28MP/ME:5# show sntp
Command: show sntp
SNTP Information
-------------------------------------------------------------------------
Current Time Source : Local
SNTP : Disabled
SNTP Primary Server : 0.0.0.0
SNTP Secondary Server : 0.0.0.0
SNTP Poll Interval : 30 sec
DGS-1210-28MP/ME:5#
enable sntp
Purpose
To enable SNTP server support.
Syntax
enable sntp
Description
The
enable sntp
command enables SNTP server support. SNTP
service must be separately configured (see
config sntp
). Enabling
and configuring SNTP support override any manually configured
system time settings.
Parameters
None.
Restrictions
Only administrator and Operator-level users can issue this
command. SNTP settings must be configured for SNTP to function
(
config sntp
).
Example usage:
Содержание DGS-1210/ME series
Страница 61: ...DGS 1210 ME Metro Ethernet Switch CLI Reference Guide 41 Sending mail please wait Success DGS 1210 28MP ME 5 ...
Страница 186: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 166 DGS 1210 28MP ME 5 ...
Страница 190: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 170 Success DGS 1210 28MP ME 5 ...
Страница 386: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 366 Port Max Group 1 v6 256 3 v6 256 DGS 1210 28MP ME 5 ...