![D-Link DGS-1210/ME series Скачать руководство пользователя страница 110](http://html.mh-extra.com/html/d-link/dgs-1210-me-series/dgs-1210-me-series_reference-manual_77989110.webp)
DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
90
show snmp user
Purpose
To display information about each SNMP username in the SNMP
group username table.
Syntax
show snmp user
Description
The
show snmp user
command displays information about each
SNMP username in the SNMP group username table.
Parameters
None.
Restrictions
None.
Example usage:
To display the SNMP users currently configured on the Switch:
DGS-1210-28MP/ME:5# show snmp user
Command: show snmp user
Username Group Name SNMP Version Auth-Protocol PrivProtocol
-------------- ---------------- ---------------- -------------------- ---------------
ReadOnly ReadOnly V1 None None
ReadOnly ReadOnly V2 None None
ReadWrite ReadWrite V1 None None
ReadWrite ReadWrite V2 None None
Total Entries: 4
DGS-1210-28MP/ME:5#
create snmp view
Purpose
To assign views to community strings to limit which MIB objects an
SNMP manager can access.
Syntax
create snmp view <view_name 32> <oid 32> <oid_mask 32
view_type [included | excluded]
Description
The
create snmp view
command assigns views to community
strings to limit which MIB objects an SNMP manager can access.
Parameters
<view_name 32>
− A string of up to 30 alphanumeric characters that
identifies the SNMP view to be created.
<oid 32>
− The object ID that identifies an object tree (MIB tree) to
be included or excluded from access by an SNMP manager.
<oid_mask 32>
− The object ID mask that identifies an object tree
(MIB tree) to be included or excluded from access by an SNMP
manager.
included
− IncluDGS this object in the list of objects that an SNMP
manager can access.
excluded
− ExcluDGS this object from the list of objects that an
SNMP manager can access.
Restrictions
Only administrator, operate or power user-level users can issue this
command.
Содержание DGS-1210/ME series
Страница 61: ...DGS 1210 ME Metro Ethernet Switch CLI Reference Guide 41 Sending mail please wait Success DGS 1210 28MP ME 5 ...
Страница 186: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 166 DGS 1210 28MP ME 5 ...
Страница 190: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 170 Success DGS 1210 28MP ME 5 ...
Страница 386: ...DGS 1210 Metro Ethernet Managed Switch CLI Reference Guide 366 Port Max Group 1 v6 256 3 v6 256 DGS 1210 28MP ME 5 ...