The LAMPII system consists of the following:
A
LAMPII Transporter
•
Self-propelled wheeled transporter
•
Integrated pan/tilt/zoom (OZIII camera) mainline camera with
LED lightheads and homing
•
Integrated lateral push assembly (2-speed)
•
Lateral footage encoder
•
Built-in diagnostics
The LAMPII launcher is a wheeled transporter with integrated pan and tilt/
zoom camera and lateral push cable assembly. The LAMPII lateral push
cable assembly propels the small push camera from inside the mainline
pipe into the lateral. The launcher is a wheeled transportation platform
which transports the entire LAMPII system through the mainline sewer
pipe. The integrated pan and tilt/zoom camera provides live video of the
mainline sewer pipe inspections. The mainline camera is mounted on the
front of the LAMPII transporter, which pans and tilts/zooms to monitor
the insertion of the lateral camera and view the mainline pipe. The unit
includes two LED lightheads on the camera to provide adequate lighting
for a clear picture of the mainline and lateral pipelines. The camera head
pivots for easy insertion into the pipe.
B
Lateral Camera & Cable Assembly
•
Self-upright camera with LED light-ring
•
Camera centering ball
•
Steel spring push cable (LM350 & LM350-3 with stainless steel cable option up to 100 ft)
•
Fiberglass push cable (LM350-2 & -4 to -10 with fiberglass cable options up to 180 ft)
•
Sonde (optional)
The lateral camera is fixed to the push cable (stainlees steel or fiberglass cable assembly, depending on
your specific configuration) and is propelled into the lateral by the LAMPII push assembly. The mini-camera
light ring contains (12) adjustable-intensity, light-emitting diodes. The camera centering ball protects
the lateral camera and lighthead from offsets and in-line obstructions and helps negotiate bends during
the pipe inspection. An optional sonde, built into the lateral mini-camera, is available to help accurately
locate the camera in metallic and non-metallic pipes. The sonde can operate with any constant tone,
512Hz locator/receiver.
EQUIPMENT OVERVIEW
A
B
Содержание LAMP II
Страница 1: ...LAMP II OPERATION MAINTENANCE MANUAL P N LM903 Revision 18 120220 Lateral Mainline Probe II CUES...
Страница 29: ...4 CUES Inc LAMPII User Manual LM903 25 www cuesinc com salesinfo cuesinc com...
Страница 35: ...4 CUES Inc LAMPII User Manual LM903 31 www cuesinc com salesinfo cuesinc com...
Страница 53: ...5 CUES Inc LAMPII User Manual LM903 49 www cuesinc com salesinfo cuesinc com CUES...