108
Gas Alarm
0x12
Event /Cleared
0x00
- Event identifier for the event
which is no more active.
- If no Event Parameter is
provided, there are no active events
for the specified Notification Type.
Combustible Gas Detected
0x01
Node Location Report
(Node Naming and Location
Command Class)
Combustible Gas Detected,
Unknown Location
0x02
Toxic Gas detected
0x03
Node Location Report
(Node Naming and Location
Command Class)
Toxic Gas detected, Unknown
Location
0x04
Gas Alarm Test
0x05
Replacement Required
0x06
Unknown Event
0xFE
Notification Type
Event
Parameter(s)
Request pending
notification
(Notification Get;
pull mode)
0xFF
3.8.2.2 Power Level Settings
This is used to set the power level indicator value, which should be used by the node when transmitting
RF, and the timeout for this power level indicator value before returning the power level defined by the
application.
Power Level:
The power level indicator value to set.
Valid levels are: NormalPower, minus1dBm, minus2dBm, minus3dBm, minus4dBm, minus5dBm,
minus6dBm, minus7dBm, minus8dBm and minus9dBm.
Timeout value is ignored if Power level is set to NormalPower.