102
Heat
Alarm
0x04
Event /Cleared
0x00
- Event identifier for the event
which is no more active.
- If no Event Parameter is
provided, there are no active
events for the specified
Notification Type.
Overheat detected
0x01
Node Location Report (Node
Naming and Location Command
Class)
Overheat detected,
Unknown Location
0x02
Rapid Temperature Rise
0x03
Node Location Report (Node
Naming and Location Command
Class)
Rapid Temperature Rise,
Unknown Location
0x04
Under heat detected
0x05
Node Location Report (Node
Naming and Location Command
Class)
Under heat detected,
Unknown Location
0x06
Unknown Event
0xFE
Notification Type
Event
Event Parameter(s)
Water
Alarm
0x05
Event /Cleared
0x00
- Event identifier for the event
which is no more active.
- If no Event Parameter is
provided, there are no active
events for the specified
Notification Type.
Water Leak detected
0x01
Node Location Report (Node
Naming and Location Command
Class)
Water Leak detected,
Unknown Location
0x02
Water Level Dropped
0x03
Node Location Report (Node
Naming and Location Command
Class)
Water Level Dropped,
Unknown Location
0x04
Replace Water Filter
0x05
Water Flow Alarm
0x06
Water Pressure Alarm
0x07
Unknown Event
0xFE
Notification Type
Event
Event Parameter(s)
Access
Control
0x06
Event /Cleared
0x00
- Event identifier for the event
which is no more active.
- If no Event Parameter is
provided, there are no active
events for the specified
Notification Type.
Manual Lock Operation
0x01
Manual Unlock Operation
0x02
RF Lock Operation
0x03
RF Unlock Operation
0x04
Keypad Lock Operation
0x05
User Code Report (User Code
Command Class V1)
Keypad Unlock Operation
0x06
User Code Report (User Code