7.1.1.1 Custom Input Description of Use (DTS, VTS, TSB)
Basket Left (I6):
This control input is used to tell the EZT that the basket
(DTS/TSB) is in the left position/hot bath. There is no user
indication for this input.
Basket Right (I7):
This control input is used to tell the EZT that the basket
(DTS/TSB) is in the right position/cold bath. There is no user
indication for this input.
Basket Up (I30):
This control input is used to tell the EZT that the basket
(VTS/TSB) is in the hot chamber/unload position. There is no
user indication for this input.
Basket Down (I31):
This control input is used to tell the EZT that the basket
(VTS/TSB) is in the cold chamber/down position. There is no
user indication for this input.
TSB Pump Pressure Safety (I45):
The pump pressure safety input is used on TSB’s to indicate that
the hot or cold bath fluid pump has exceeded its maximum
operating pressure. This input is active low, i.e., the input must
be off in order for the alarm to be indicated. When active (input
off), the EZT shuts down the chamber until the alarm is
acknowledged (silence button pressed on alarm monitor screen)
and the input is off.
Bath Level Safety (I46):
The bath level safety input is used on TSB’s to indicate that a
bath is low on fluid (if equipped with level sensors). This input is
active high, i.e., the input must be on in order for the alarm to be
indicated. When active (input on), the EZT will sound the alarm
to obtain operator attention but will not shut down the chamber.
The alarm will be shown on the system status monitor screen.
Содержание EZT-570i
Страница 1: ...EZT570i Technical Manual Rev B EZT 570i Technical Manual...
Страница 14: ...EZT 570i Technical Manual 14 4 1 6 Conditioning System Logic Flow...
Страница 15: ...EZT 570i Technical Manual 15...
Страница 19: ...EZT 570i Technical Manual 19 4 2 2 Humidity System Logic Flow...
Страница 21: ...EZT 570i Technical Manual 21 4 3 2 Auxiliary Cooling System Logic Flow...
Страница 23: ...EZT 570i Technical Manual 23 4 4 2 Dry Air Purge System Logic Flow...
Страница 25: ...EZT 570i Technical Manual 25 4 5 2 Altitude System Logic Flow...
Страница 29: ...EZT 570i Technical Manual 29 4 7 2 Transfer System Logic Flow...
Страница 30: ...EZT 570i Technical Manual 30...
Страница 58: ...EZT 570i Technical Manual 58 7 2 Standard Output Configuration...
Страница 92: ......
Страница 93: ...EZT 570i Technical Manual 1 Appendix...