Use and Maintenance Manual – 08/2018 Rel. 3
Page 48
070
Lower the wheel guard to run the balancing
launch. At the end of the launch, the imbalance
data will be displayed.
If you have to balance an identical wheel, it is possible to skip the data acquisition of the balancing planes and perform immediately
with the balancing spin and then with the search for balancing planes. The balancing planes used for the calculation will be the
same as stored before by the machine.
NOTE: if the machine has been set to display the Static imbalance, the single weight will always be applied at 6 o’clock on each point
of the rim plane. Accordingly, the guided Search phase of the balancing planes is not carried out.
17.5 Use of the special Program Types for ALS2 and ALS1 aluminum wheels with laser (MEC
810VDL and MEC 820VDL)
Proceed as described below:
Phase
Description
010
Fit the wheel on the shaft and tighten with the ring nut.
020
Activate the STANDARD program by acquiring the wheel
dimensions as described in chapter 17.3.2.
030
Lower the wheel guard to run the balancing launch. At the end of
the launch the imbalance data calculated based on the balancing
planes will be displayed, and the LASER function will be activated
in automatic.