Use and Maintenance Manual – 08/2018 Rel. 3
Page 20
020
Activate the AUTO/SUV calibration program by selecting
which will turn blue.
030
Confirm activation of the AUTO/SUV calibration program by
pressing [P6]
on the keyboard.
040
Remove the wheel and any other accessories from the shaft.
050
Lower the wheel guard: the machine will run a launch.
060
Fit the wheel on the shaft.
Manually enter the wheel dimensions.
If the dimensions of the wheel were introduced before entering
the calibration program, this step can be skipped.
It is not
possible to enter the data with the automatic acquisition
system.
070
Extract the distance sensor and place it on the wheel as shown
here.
Read the distance value on the graduated scale. The distance
value is always expressed in millimeters.