This parameter controls access via the drive keypad as follows:
This parameter changes the functions of the input terminals which are normally associated with the
enabling, starting and stopping the drive.
Action will only occur if the drive is inactive. If the drive is active, the parameter will return to its pre-
altered value on exit from edit mode.
Defines the reference when jog is enabled.
Value
Text
Function
0
LEVEL.1
Access to first 10 parameters in Menu 0 only.
1
LEVEL.2
Access to all parameters in Menu 0.
2
ALL
Access to all menus.
3
StAtUS
The keypad remains in status mode and no parameters can be
viewed or edited.
4
no.Acc
The keypad remains in status mode and no parameters can be
viewed or edited. Drive parameters cannot be accessed via a
comms interface.
11
Start/Stop Logic Select
RW
Num
US
OL
Ú
0 to 6
Ö
5
RFC-A
Pr 11
Terminal 11
Terminal 12
Terminal 13
Latching
0
User programmable
Run Forward
Run Reverse
No
1
/Stop
Run Forward
Run Reverse
Yes
2
User programmable
Run
Forward/Reverse
No
3
/Stop
Run
Forward/Reverse
Yes
4
/Stop
Run
Jog Forward
Yes
5
User programmable
Run Forward
Run Reverse
No
6
User programmable
User
programmable
User
programmable
User
programmable
15
Jog Reference
RW
Num
US
OL
Ú
0.00 to 300.00 Hz
Ö
1.50 Hz
RFC-A