42
Unidrive M300/HS30 Quick Start Guide
Issue Number: 7
Defines the functionality of Analog Output 1 (terminal 7).
Defines the maximum switching frequency that can be used by the drive.
See the
Power Installation Guide
for drive derating data.
36
Analog Output 1 Control
RW
Txt
US
OL
Ú
0 to 14
Ö
0
RFC-A
Value
Description
0
User defined by Analog Output 1 Source A
1
Frequency output
2
Frequency reference
3
Motor speed
4
Current Magnitude
6
Torque output
7
Torque current output
8
Voltage output
9
DC bus voltage (0~800 V)
10
Analog Input 1
11
Analog Input 2
12
Power output (0~2 x Pe)
13
Torque limitation
14
Torque reference (0~300 %)
37
Maximum Switching Frequency
RW
Txt
US
OL
Ú
0.667 (0), 1 (1), 2 (2), 3 (3), 4 (4),
6 (5), 8 (6), 12 (7), 16 (8) kHz
Ö
3 (3) kHz
RFC-A
2 (2), 3 (3), 4 (4), 6 (5), 8 (6), 12 (7),
16 (8) kHz
Pr 37
Text
Description
0
0.667
667 Hz switching frequency
1
1
1 kHz switching frequency
2
2
2 kHz switching frequency
3
3
3 kHz switching frequency
4
4
4 kHz switching frequency
5
6
6 kHz switching frequency
6
8
8 kHz switching frequency
7
12
12 kHz switching frequency
8
16
16 kHz switching frequency