Unidrive M300/HS30 Quick Start Guide
33
Issue Number: 7
Use Pr
05
to select the required frequency/speed reference as follows:
The rated current parameter must be set to the maximum continuous current of the motor (taken
from the name plate). The motor rated current is used in the following:
•
Current limits
•
Motor thermal overload protection
•
Vector mode voltage control
•
Slip compensation
•
Dynamic V/F control
05
Drive Configuration
RW
Txt
PT
US
OL
Ú
AV (0), AI (1), AV.Pr (2), AI.Pr (3),
PrESEt (4), PAd (5), PAd.rEF (6),
E.Pot (7), torquE (8), Pid (9)
Ö
AV (0)
Value
Text
Description
0
AV
Analog input 1 (voltage) or Analog input 2 (voltage) selected by terminal
(Local/Remote)
1
AI
Analog input 1 (current) or Analog input 2 (voltage) selected by terminal
(Local/Remote)
2
AV.Pr
Analog input 1 (voltage) or 3 presets selected by terminal
3
AI.Pr
Analog input 1 (current) or 3 presets selected by terminal
4
PrESEt Four presets selected by terminal
5
PAd
Keypad reference
6
PAd.rEF Keypad reference with terminal control
7
E.Pot
Electronic Potentiometer
8
torquE Torque mode, Analog input 1 (current frequency reference) or Analog input 2
(voltage torque reference) selected by terminal
9
Pid
PID mode, Analog input 1 (current feedback source) and Analog input 2
(voltage reference source)
A change to Pr
05
is set by pressing the ENTER button on exit from parameter edit mode.
The drive must be disabled, stopped or tripped for a change to take place. If Pr
05
is
changed while the drive is running, when the ENTER button is pressed on exit from
parameter edit mode, Pr
05
will change back to its previous value.
When the setting of Pr
05
is changed, the appropriate drive configuration parameters are
set back to their default values.
06
Motor Rated Current
RW
Num
RA
US
OL
Ú
0.00 to Drive Rating A
Ö
Maximum Heavy
Duty Rating A
RFC-A
NOTE
NOTE