34
Unidrive M300/HS30 Quick Start Guide
Issue Number: 7
Set to the rated speed of the motor (taken from the motor name plate). The motor rated speed is
used to calculate the correct slip speed for the motor.
* With Unidrive HS30, the maximum is 80,000.0 rpm.
The Rated Voltage (Pr
08
) and the Rated Frequency (Pr
39
) are used to define the voltage to
frequency characteristic applied to the motor. The Rated Frequency (Pr
39
) is also used in
conjunction with the Motor Rated Speed (Pr
07
) to calculate the rated slip for slip compensation.
Enter the motor rated power factor cos
ϕ
(taken from the motor name plate).
The drive can measure the motor rated power factor by performing a rotating autotune (see Autotune
(Pr
38
).
07
Motor Rated Speed
RW
Num
US
OL
Ú
0.0 to 33000.0 rpm*
Ö
Def.50: 1500.0 rpm
Def.60: 1800.0 rpm
RFC-A
Def.50: 1450.0 rpm
Def.60: 1750.0rpm
08
Motor Rated Voltage
RW
Num
RA
US
OL
Ú
0 to 240 V or 0 to 480 V
Ö
110 V drive: 230 V
200 V drive: 230 V
400 V drive 50 Hz: 400 V
400 V drive 60 Hz: 460 V
RFC-A
09
Motor Rated Power Factor
RW
Num
RA
US
OL
Ú
0.00 to 1.00
Ö
0.85
RFC-A
10
User Security Status
RW
Num
ND
PT
US
OL
Ú
LEVEL.1 (0), LEVEL.2 (1),
ALL (2), StAtUS (3), no.Acc (4)
Ö
LEVEL.1 (0)
RFC-A