Unidrive M300/HS30 Quick Start Guide
25
Issue Number: 7
5.1 Saving parameters
When changing a parameter in Menu 0, the new value is saved when pressing the Enter button
to return to parameter view mode from parameter edit mode.
If parameters have been changed in the advanced menus, then the change will not be saved
automatically. A save function must be carried out.
Procedure
1. Select ‘Save' in Pr
00
or
Pr
mm.000
(alternatively enter a value of 1001 in Pr
00
or
Pr
mm.000
)
2. Either:
•
Press the red
reset button
•
Carry out a drive reset through serial communications by setting Pr
10.038
to 100
5.2 Restoring parameter defaults
Restoring parameter defaults by this method saves the default values in the drives memory.
User
Security Status
(Pr
10
) and
User Security Code
(Pr
25
) are not affected by this procedure.
Procedure
1. Ensure the drive is not enabled, i.e. drive is in inhibit or under voltage state.
2. Select 'Def.50’ or 'Def.60' in Pr
00
or
Pr
mm.000
(alternatively, enter 1233 (50 Hz settings) or
1244 (60 Hz settings) in Pr
00
or
Pr
mm.000
).
3. Either:
•
Press the red
reset button
•
Carry out a drive reset through serial communications by setting Pr
10.038
to 100