Unidrive M300/HS30 Quick Start Guide
29
Issue Number: 7
* Setting Pr
07
to 0.0 will disable slip compensation. With the Unidrive HS30, the maximum is 80,000.0 rpm.
** Following a rotating autotune, Pr
09
is continuously written to by the drive, calculated from the value of
Stator
Inductance
(Pr
05.025
). To manually enter a value into Pr
09
, Pr
05.025
will need to be set to 0. Refer to the
description of Pr
05.010
in the
Parameter Reference Guide
for further details.
*** With the Unidrive HS30, the maximum is 3000.00 Hz.
**** If this parameter is read via serial communications, it will show pole pairs.
***** With the Unidrive HS30, the maximum is 180,000.0 rpm.
93
Jog Select
Off (0) or On (1)
RO
Bit
ND NC PT
94
Analog Input 1
± 100.00 %
RO Num ND NC PT FI
95
Analog Input 2
± 100.00 %
RO Num ND NC PT FI
RW
Read /
Write
RO
Read
only
Num
Number
parameter
Bit
Bit
parameter
Txt
Text string Bin
Binary
parameter
FI
Filtered
ND
No
default
value
NC
Not
copied
PT
Protected
parameter
RA
Rating
dependent
US
User save
PS
Power-down
save
DE Destination
Parameter
Range
(
Ú
)
Default
(
Ö
)
Type
OL
RFC-A
OL
RFC-A