Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 75 of 108
6.4.3.11
Mount pickup guide
For areas in which it is necessary to travel in or out of the conductor rail system, pickup guides are used in combination with the
current collectors provided for this purpose. It should be noted that the maximum speed at pickup guides is 80 m/min, and pickup
guides are classified as wear parts. The installation tolerances must be observed. Simultaneous offsets with the maximum tolerances
in the x- and y-directions are not permitted.
The pickup guide centers the current collector with a maximum lateral and vertical offset of ± 25 mm (settings of less than ± 10 mm
are recommended).
NOTE!
For systems with pickup guides, there must be an appropriate number of current collectors
installed at an interval that ensures that the minimum number of current collectors required for
the current demand is always engaged. (see Fig. 104 below).
WARNING!
De-energize current collectors or protect them against contact!
The user must ensure that current collectors located between the pickup guides are de-energized
or protected against accidental contact.
Fig. 103: Installation dimensions of the pickup guide
Dimension [mm]
Number of poles
1
2
3
4
5
a
200
265
330
395
460
b
105
170
235
300
365