NOTE!
Current collector capacity:
The current collector capacity is defined by the connected cable as well as sliding contacts used and is
typically lower (see catalog)! Ambient temperatures and operating modes result in reduced current
collector capacity (e.g., operating at a standstill, operating at elevated temperatures).
Chemical resistance
Insulating material
PVC: Good general chemical resistance
PPE: Average chemical resistance, critical when in direct contact with oils, not suitable
for outdoor use in direct sunlight.
Installation material
PC, PA, PBT: Good general chemical resistance, partly limited
Conductor bar material
Aluminum with stainless steel sliding surface
CopperECO
Copper
Information regarding resistances are general notes and depend on the temperature, exposure time, concentration and interactions and must be
verified in individual cases. Before usage in critical environmental conditions such as chemical operations, galvanizing plants, compost works and
warehouses and locations with high concentrations of aromatic compounds, benzene and other substances from these material groups, we ask
that you please contact us for the purpose of alternative installation positions and materials and possibly
necessary additional components
.
Insulating profile
Material
Stabilized rigid PVC (standard material) and PPE + SB (heat-resistant version for indoor
applications)
Flammability
Compliant with requirements for insulating materials according to UL94 V-1; flame-
retardant and self-extinguishing (IEC60695-11-10 ); PPE + SB halogen free
Note: Under certain framework conditions, individual data is only valid to a limited extent.