Mount each line feed in the same way.
NOTE!
Do not allow any tensile stress on the line feed!
→
Provide the line feed with a strain relief at a suitable distance.
WARNING!
Avoid destroying the conductor rail!
→
Do not slide the conductor rails together with force.
→
Do not strike them with a hammer.
→
Observe the tightening torques and use a torque wrench.
→
Use contact grease (Order No.: 080021).
Use the QR code ("click" or "scan") to see our animation
Connecting Rails and Mounting
Line Feed
6.4.3.6
Mount anchor clamp
The conductor rail is fixed at one point by means of anchor clamps and can expand freely from this point. The fixed point is typically
attached near the line feed. If several fixed points are projected, for example, with transfers or curves (natural fixed point), decouple
the route between the fixed points using expansion units. Attachment of the anchor clamp occurs through a clamping cone on the
insulating profile.
The conductor rail can normally slide into the hanger clamp. The conductor rail is mechanically fixed
within the support structure/substructure using fixed points. It makes sense to always position fixed
points of the conductor rail at fixed point positions of the supporting structure.