Fig. 23: Air gap 0813
◼
Air gap 08119*-**
Air gaps are used for galvanic isolation of sections that can
be fed in and disconnected from the power separately, e.g.,
for maintenance lines. For each isolation point, 2 air gaps
are installed at a suitable distance to avoid voltage leak
across the current collector.
Fig. 24: Expansion unit 0813
◼
Expansion unit 081362-5X21XX
To compensate for temperature-related changes in length
for
systems > 200 m or sections of the route that are
integrated between two fixed points, such as pickup guides
at both ends of the section, expansion units are required to
accommodate the change in length. The expansion unit has
two expansion points, each of which can accommodate a
maximum 45 mm expansion. The expansion units are
delivered pre-assembled on a conductor rail (5000 mm). The
middle section of the expansion unit must be supported with
a hanger clamp (not included in the scope of delivery) on the
customer's support structure/substructure.
The use of a double current collector is recommended when
using expansion units.
Fig. 25: Pickup guide 0813
◼
Pickup guide 08138***
For areas in which it is necessary to travel in and out of the
conductor rail system, pickup guides are used in
conjunction with the current collectors intended for the
purpose. It should be noted that the maximum speed for
the pickup guides is 80 m/min, and pickup guides are
classified as wear parts. The installation tolerances must
be observed. Simultaneous offsets with the maximum
tolerances in the x- and y-directions are not permitted.
DANGER!
Hazard due to exposed current collectors!
The user must ensure that while the current collectors are between transfer pickup guides, they are
de-energized or protected against accidental contact.