Technical Data
System
Insulated conductor rail system for use in supplying energy to crane systems, the
construction of larger slip ring arrangements, transfer carriages, cable tracks or similar
moving consumers mounted in non-publicly accessible areas, out of hands' reach in
indoor areas and weather-protected outdoor areas (IP2x).
Installation orientation
Current collector insertion from below; current collector insertion from the side is also
possible in indoor areas.
Rail length
5000 mm (nominal size at 20° C/tolerance ± 3 mm)
Phase offset
80 mm (standard)/70 mm (reduced with offset current collector arrangement)
Suspension interval
2.5 m/typically 2.4 to 2.5 m
Maximum system length
Unlimited
Travel speed
Maximum 600 m/min (straight line without interruption)
Permitted ambient temperature
*
-15°C to +55°C (85°C in heat-resistant version/PPE + SB) [Lower temperatures on
request. At lower temperatures, flexible lines should be used.]
Maximum temperature difference
∆ K 40° C
Maximum conductor temperature
+85°C (115°C for heat-resistant version/PPE + SB, briefly 125°C)
Protection type
With current collector insertion from below: IP23 (DIN EN 60529, VDE 0470-1); with
current collector insertion from the side: IP21
Storage temperature
-30°C to +40°C (store in a dry place dry, avoid condensation)
Minimum installation temperature
-10°C (recommended installation temperature: Above 0°C)
Local approvals
UL/CSA/EAC
Max. Air humidity at +40° C
85% rel. H/non-condensing
Altitude above sea level
≤ 2000 m
Travel direction
Forward and backward (reversing)
* Note: At temperatures below -10°C, the mechanical load must be limited through physically limiting the breaking strength.
Conductor bar material
Aluminum with stainless
steel sliding surface
CopperECO
Copper
Type
081313 081314 081319 08131C 08131D 08131I 081315 081316 081317
Current load [A] at 100% DC
and 35°C (rated value)
at 60% DC
500
510
800
810
1000
1050
500
510
800
810
1000
1050
500
520
800
880
1250
1400
Rated voltage
[V]
690 (UL 600 V) - min. 24 V/1 A (minimum load)
Ohmic resistance at
+35°C [Ω/1000 m]
+ 20°C [Ω/1000 m]
0.097
0.092
0.074
0.071
0.051
0.049
0.097
0.092
0.074
0.071
0.051
0.049
0.104
0.097
0.057
0.054
0.033
0.031
Impedance at +20°C [Ω/1000 m]
Impedance at +20°C [Ω/1000 m]
0.157
0.152
0.144
0.140
0.137
0.134
0.157
0.152
0.144
0.140
0.137
0.134
0.161
0.156
0.136
0.134
0.127
0.126