Fig. 53: Slide the next hanger clamp onto the support arm
Fig. 54: Align the hanger clamps using the mounting comb
→
In order to achieve an even phase offset, the next hanger clamps must be aligned with the mounting comb (see Fig. 54). The
phase offset of either 80 mm (standard) or 70 mm (reduced) can be set with the mounting comb. Depending on which phase
offset is to be implemented, the corresponding side (4x80 mm or 4x70 mm) of the mounting comb must be used (see Fig. 55).
Fig. 55: Dimensions on the mounting comb
→
After the hanger clamps have been aligned, tighten the next hanger clamps with an open-end wrench SW 17 (14 Nm) and
remove the mounting comb. The retaining clamp of the hanger clamp must be rotatable. A subsequent alignment is not
necessary.
→
Mount the other hanger clamps in the same way.