ANSI Z359.14 Class B

ANSI A10.32

CSA Z259.2.2-98 Type 1

OSHA

This manual is intended to meet the Manufacturer’s 

Instructions as required by the above listed standards 

and should be used as part of an employee training 

program as required by OSHA.

INSTRUCTION MANUAL

Figure 1  –  Rebel™ Self Retracting Lifeline Models

A - Steel Carabiner

B - Steel Snap Hook

C - Steel Swiveling Snap Hook

D - Steel Rebar Hook

Swivel End

Lifeline End

Model

Swivel End

Lifeline End

A - 2000192

(Optional)

Single SRL Models

B

C

D

ANSI

3100400

1

3100401

1

3100402

1

3100403

1

1

3100404

1

1

3100405

1

1

CSA

3100406

1

3100407

1

3100408

1

3100409

1

1

3100410

1

1

3100411

1

1

A - 2000192

Twin SRL Harness Mount Models

B

C

D

ANSI

3100412

1

2

3100413

1

2

3100414

1

2

CSA

3100415

1

2

3100416

1

2

3101257

1

2

© 3M 2017

FORM NO: 5903744 

REV: C

SELF RETRACTINg LIFELINES

Model Numbers:

 (See Figure 1)

 

Содержание Protecta series

Страница 1: ...arabiner B Steel Snap Hook C Steel Swiveling Snap Hook D Steel Rebar Hook Swivel End Lifeline End Model Swivel End Lifeline End A 2000192 Optional Single SRL Models B C D ANSI 3100400 1 3100401 1 3100...

Страница 2: ...Before using this equipment record the product identification information from the ID label in the inspection and maintenance log of this manual DESCRIPTIONS Figure 2 illustrates key components of the...

Страница 3: ...2 in 1 07 m 2 3 ANCHORAGE Anchorages selected for fall arrest systems shall have a strength capable of sustaining static loads applied in the directions permitted by the system of at least 1 5 000 lbs...

Страница 4: ...ifeline from retracting or being taut Avoid slack line Do not lengthen SRL by connecting a lanyard or similar component without consulting 3M Fall Protection 2 9 FALL CLEARANCE Figure 3A illustrates F...

Страница 5: ...f clearance is required when the Rebel unit is anchored 3 1 2 ft 1 m above and 3 1 2 ft 1 m to the side of the user s harness dorsal connection NOTE The clearances provided above assume the fall occur...

Страница 6: ...features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point D To each other E Directly to webbing or rope...

Страница 7: ...Snap Hook Twin SRL Harness Mounting using a Carabiner Some Rebel SRL models include a Carabiner identified in Figure 2 which can connect two Rebel SRLs to a Full Body Harness when climbing applicatio...

Страница 8: ...nnections for Rebel SRL Fall Arrest Systems When using a hook to make a connection ensure roll out cannot occur see Figure 4 Do not use hooks or connectors that will not completely close over the atta...

Страница 9: ...L and horizontal system components must be compatible Horizontal systems must be designed and installed under the supervision of a qualified engineer Consult the horizontal system equipment manufactur...

Страница 10: ...10 Figure 8 Rebel SRL System Connections B C A E C E B A C B C A Dorsal D Ring B Carabiner C Snap Hook D Rebar Hook E Anchorage Point Figure 9 100 Tie Off Figure 10 Incorrect Attachment 1 2 3...

Страница 11: ...housing causing a potential free fall hazard IMPORTANT If the lifeline contacts acids or other caustic chemicals remove the SRL from service and wash with water and a mild soap solution Inspect the S...

Страница 12: ...uts and abrasions The lifeline must be free of knots throughout its length Inspect for excessive soiling paint build up and rust staining Inspect for chemical or heat damage indicated by brown discolo...

Страница 13: ...13 Figure 14 Labeling...

Страница 14: ...ON DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved...

Страница 15: ...nstalaciones para evaluar los reclamos sobre la calidad Esta garant a no cubre los da os ocasionados por el desgaste el abuso el mal mantenimiento o como consecuencia del traslado del producto u otros...

Страница 16: ...3Mfallprotection ca mmm com EMEA Europe Middle East Africa EMEA Headquarters 5a Merse Road North Moons Moat Redditch Worcestershire B98 9HL UK Phone 44 0 1527 548 000 Fax 44 0 1527 591 000 informatio...