4 - 4 2
l O p e r a t i o n
O p e r a t i n g S c r e e n s
( c o n t i n u e d )
Disabled
: Loader body is disabled. Loading to this loader body is not controlled or moni-
tored.
Enabled
: Loader body is enabled. Loading to loader body is controlled and monitored, and
it currently is satisfied with material.
Request/Demanding
: The loader body is requesting/demanding a fill sequence from the
pump. The demand should be in the first in/first out queue of the pump and is waiting its
turn in the cycle.
Filling
: The loader body is currently being serviced by the pump and is being filled with
material.
Discharging/Dumping
: The loader body fill sequence has completed and it is currently
dumping material.
Disabled
: The blower is disabled. The pump is not being monitored or controlled and any
first-in / first - out loading queues are clear.
Enabled
: The blower is enabled and not running. The pump is waiting for a fill request
from a loader body.
Request/Demand
: The blower has received a request by a loader to run a fill sequence for
the loader body.
Running
: The blower is currently turned on and providing a fill sequence to a loader body.
Idling
: The blower is currently idling. No loader bodies are requesting material since the
last loader body was serviced. The pump will continue to run until the desired ‘Idle’ time
has concluded.
(Continued)