O p e r a t i o n l
4 - 4 5
4
Opera
tion
S e t u p S c r e e n s
S e t u p a n d C o n f i g u r a t i o n
Setup is used to configure the TrueBlend SB-4 systems operating parameters - the calibra-
tion, the blender model number, number of component bins, batch hopper weight and other
parameters. It also contains the configuration menus for remote communication protocols
and all TrueBlend SB-4 Maintenance and Diagnostic functions. Each Setup parameter is
configured and then stored in permanent memory.
To navigate to the <Setup> screen, first navigate to the <Home> page. At the <Home>
screen press the [More...] button. Press the button labeled [Setup] and the screen will
change to the main <Setup> screen.
The setup screens are organized to group the configuration parameters by the type of device
(System, Panel, Component, Batch Hopper, Mixer, Network, and Maintenance). The vari-
ous device types are chosen by ‘Selection’ buttons shown across the TOP of the screen. For
each device, relevant parameters are further grouped into sections. Each section is chosen
using ‘Selection’ buttons along the Left side of the screen. With this method it is very easy
to navigate through-out the setup system with a minimal amount of screen navigation and
user interaction.
All setup parameters can be viewed by the user; however the current security level and
operating state will dictate whether or not the parameters can be adjusted. If while in setup,
a parameter needs to be changed, touch the desired input field. If the user does not have
proper security a security popup screen will appear, where the user can input a new security
passcode. If the system operating state does not allow a parameter field to be edited, a secu-
rity popup screen will appear informing the user the system state must be changed before
editing the selected field. If the user enters the correct passcode, the field will become
editable. Locked parameters will have a darkened background.
In case it is necessary to reset the system to a default state, there is a [Factory Default] but-
ton provided which will erase all memory and reset the entire configuration back to an ini-
tial default state. This button can be found in the <Maintenance> section of setup.
Setup Devices
System
: This device contains setup parameters that define the physical configuration of the
blender, the methods by which production recipes are entered, and the severity and process-
ing of alarm states.
Panel
: This device contains parameters which define the appearance of the touchscreen and
the security requirements for user actions
NOTE:
After changing any setup parameter, DO NOT power down without first returning to the
<HOME> screen and waiting for at least a minute. The system requires this time to store
any parameter changes to the Compact Flash CF card installed in the touch screen.
✐
NOTE:
If the system requires a reboot sequence, a ‘Reboot Requested’ popup will be displayed.
After the configuration has been saved, the system will automatically perform a reboot
sequence.
✐