S e t u p S c r e e n s
( c o n t i n u e d )
S e l f l o a d i n g S e t u p
The blender has the capability to provide self-loading. IT will monitor requests for loads
from the receiver bodies and then sequence the receiver valves and the blower pump to load
material. This feature requires an unlock code. Once unlocked the setup page will provide
two additional setup buttons on the device bar for setting up both the loaders and the blower
pump.
Blower
Control parameters to control the pump/blower device for the self-loading feature.
The basic blower settings are:
NOTE:
With the self-loading system it is possible to provide loading feature for loaders that are
located on a second blender. The (2) blenders must be connected via an Ethernet connec-
tion. The configuration of the loaders includes a remote setting for specifying where the
blower resides. A full explanation of how this system is configured will be explained.
✐
Parameter
Default
Range
Security
Description
Name
Blower x [14 character string] Setup/Stop
The name of the blower pump.
Blower Address
NodeID
[1:255]
Setup/Stop
The Node ID of the touch-panel where the pump
resides. The Node ID is configured via <Setup> -
<IP Address> screen.
Idle Mode
No
Yes/No
Setup/Stop
Select Yes to enable software control of the idle
mode for the pump.
Idle Time (sec)
600
[0:600]
Setup/Stop
The amount of time the pump will run in idle mode
before stopping.
Secondary Pump
Enable
No
Yes/No
Setup/Stop
Once enabled, the secondary pump will be available
as a backup pump.
Selected Pump
Primary
Primary/Secondary
Setup/Stop
Select which pump the primary or secondary pump
will be used for loading the receiver bodies. For the
secondary pump, it must first be enabled.
Secondary Pump
Starter Slot
13
[1:15]
Setup/Stop
The PLC Slot where the secondary pump starter is
connected.
Secondary Pump
Starter Channel
1
[1:12]
Setup/Stop
The PLC IO channel for secondary pump starter.
Primary Pump
Starter Slot
8
[1:15]
Setup/Stop
Select The PLC Slot where the primary pump
starter is connected.
Primary Pump
Starter Channel
9
[1:12]
Setup/Stop
The PLC IO channel for the primary pump starter.
4 - 8 4
l O p e r a t i o n
(Continued)