S e t u p S c r e e n s
( c o n t i n u e d )
•
Save/Retrieve Configuration:
The full configuration of the system can be saved or
retrieved. This is useful in the event that a firmware update is required; the existing
system configuration can be saved then reloaded after the firmware update is complet-
ed. Also Conair service often will request the configuration files in order to diagnose
issues with the system. After performing a retrieval of the configuration, the system
will perform a reboot sequence upon returning to the <Home> screen.
Multiple files are used for the configuration so selecting an individual file for this task
is not available. The default directory for the configuration files is (CfgFiles).
•
Save/Retrieve Recipe:
The recipe book can be saved or retrieved. In the event of a
firmware update, the recipe book can be saved and reloaded after the firmware update
is completed. With identical systems, it is also possible to copy the recipe book from
one system to another.
The default path for the recipe book is (/DatFiles/RecipLst.csv).
•
Save/Retrieve Resin:
The list of resins can be saved or retrieved. In the event of a
firmware update, the resin list can be saved and reloaded after the firmware update is
completed. With identical systems, it is also possible to copy the resin list from one
system to another.
The default path for the resin list is (/DatFiles/ResinLst.csv).
•
Save Diagnostics:
This option will save mul-
tiple diagnostic files to the hard-drive. Files
included will be the system configuration,
feed tables, batch data, mixer state, and the
alarm log. These files are typically used by
Conair service to diagnose issues with the
system. This provides a simpler method of
obtaining diagnostic files without having to
individually select them.
The destination drive is the only selectable
path option for this option. The various data
files will be stored in the (Diagnostics) direc-
tory on the specified drive.
•
Save Batch Data:
This option will save the batch statistics for the last 50 batches.
The default path for the batch statistics is (/DatFiles/BatchStats.csv).
•
Save Feed Tables:
This option will save the feed / material calibration data for each of
the component hoppers. If extrusion control is also available, the rate tables for the
extruder and the haul-off devices will also be saved.
The default path for the feed tables is (/DatFiles/FeedTbl.csv).
4
Opera
tion
O p e r a t i o n l
4 - 8 1
(Continued)
Содержание TrueBlend SB-4
Страница 6: ...iv l Table of Contents...
Страница 38: ...3 10 l Installation...
Страница 134: ...4 96 l Operation...
Страница 160: ...6 10 l Troubleshooting...
Страница 165: ...Appendix l C 2 Hole Locations for Blow Off Kit...
Страница 168: ...D 3 l Appendix...