Time
This page is used to configure the times for loading and dumping the receivers. Each loader
has its own set of settings. Select the loader by name using the selection buttons along the
right side of the screen.
The basic loader time settings are:
Parameter
Default Range
Security Description
Load Time (sec)
10
[2:180]
Operator The amount of time the receiver body will load with material.
Dump Time (sec) 5
[2:180]
Operator The amount of time the receiver body will dump the material.
First Fill (sec)
5
[2:600]
Operator This time allows an empty hopper to be filled for a designated time
period before an alarm will be generated. The time starts when the
loader is turned on.
Alarm Time (sec) 120
[0:3600] Operator This is the amount of time the hopper will be loaded (after the first
fill time) without the demand being satisfied before an alarm will
be generated.