4 - 6 6
l O p e r a t i o n
S e t u p S c r e e n s
( c o n t i n u e d )
Calibration Procedure {Operator / Stop}
1
Press the [Manual Calibrate] button. It is a good idea to re-calibrate the unit after it has
been transported and mounted. Re-calibrating the unit assures that the start weight on
the scale inside the blender is zero.
Manual Calibrate
: This button will start the procedure to manually calibrate the calibra-
tion factors for the batch hopper weigh scale.
2
Press the [OK] button to obtain the Zero Weight Calibration Factor. Please stand by,
while the system obtains the Zero Weight Calibration Factor.
3
Enter the Test Weight Value, and then press [OK]. The test weight should not exceed the
capacity of the hopper else damage could result to the weighing system.
4
Place the test weight into the hopper and press [OK] to continue with the calibration.
NOTE:
The weigh bin must be in place, and empty, when you perform this task. If the bin is not in
place, the calibration will be inaccurate and will need to be redone. Once the (Zero Weight
Calibration) process has started, the procedure must be completed.
✐
(Continued)