CDM-625 Advanced Satellite Modem
Revision 1
Remote Control
MN-0000036 (Ref MN/CDM625.IOM)
D–10
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction
& Qualifier)
Response to Query
Tx Data Rate TDR=
9 bytes
Command or Query.
Tx Data rate, in kbps, between 18 kbps and 25 Mbps Resolution=1
bps
Example:
TDR=02047.999 (which is 2047.999 kbps)
Additional auxiliary G.703 sub-rates are available, selected using:
00512.AUX
01024.AUX
02048.AUX
The connectors used for the Aux rates are IDI/DDO.
These Aux rates are not available with Drop & Insert or IDR.
Read-only if Framing Mode is Quad Drop & Insert (TFM=8). Data
rate is set by assigning the number of channels on each port.
Read only if Modulation Type is a ‘Reserved’ type
TDR=
TDR?
TDR*
TDR#
TDR?
TDR=xxxxx.xxx
(see description of
arguments)
Tx
Symbol Rate
TSR=
9 bytes,
numeric
Query only.
This command allows remote access to the Tx symbol rate.
Format is ddddd.ddd
TSR?
TSR=
TSR*
TSR#
TSR?
TSR=ddddd.ddd
(see description of
arguments)
Tx
Data Invert
TDI=
Exception
600
emulation:
ITD=
1 byte, 0 or 1
Command or Query.
Invert Transmit Data
0=Normal
1=Inverted
Exception: i
n 600/L emulation mode, instruction is ITD.
Example:
TDI = 1 (selects TX Data Invert)
TDI=
TDI?
TDI*
TDI#
TDI?
Exception
600
emulation:
ITD?
TDI=x
(see description of
arguments)
Tx
Reed-
Solomon
Encoding
TRS=
1 byte, value of
0 thru 3
Command or Query.
Tx RS encoding
0=Normal (based on the Open Network framing selected)
1=IESS-310 mode, valid with QDI, unframed, IBS, D&I, IDR.
2=EF Data legacy standard (225,205) – unframed, QDI only
3=IBS (126,112) – unframed only
Example:
TRS=0
(This is a ‘don’t care’ if no RS is selected under FEC Type)
Available all framing modes, except EDMAC.
TRS=
TRS?
TRS*
TRS#
TRS?
TRS=x
(see description of
arguments)
Содержание CDM-625
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 26: ...CDM 625 Advanced Satellite Modem Revision 1 Preface MN 0000036 Ref MN CDM625 IOM xxiv Notes...
Страница 48: ...CDM 625 Advanced Satellite Modem Revision 1 Introduction MN 0000036 Ref MN CDM625 IOM 1 22 Notes...
Страница 148: ...CDM 625 Advanced Satellite Modem Revision 1 Front Panel Operation MN 0000036 Ref MN CDM625 IOM 5 76 Notes...
Страница 182: ...CDM 625 Advanced Satellite Modem Revision 1 Ethernet Management MN 0000036 Ref MN CDM625 IOM 6 34 Notes...
Страница 206: ...CDM 625 Advanced Satellite Modem Revision 1 Forward Error Correction Options MN 0000036 Ref MN CDM625 IOM 7 24 Notes...
Страница 240: ...CDM 625 Advanced Satellite Modem Revision 1 EDMAC Channel MN 0000036 Ref MN CDM625 IOM 11 4 Notes...
Страница 244: ...CDM 625 Advanced Satellite Modem Revision 1 Offset QPSK Operation MN 0000036 Ref MN CDM625 IOM 13 2 Notes...
Страница 258: ...CDM 625 Advanced Satellite Modem Revision 1 Eb No Measurement MN 0000036 Ref MN CDM625 IOM B 4 Notes...
Страница 320: ...CDM 625 Advanced Satellite Modem Revision 1 Remote Control MN 0000036 Ref MN CDM625 IOM D 60 Notes...
Страница 322: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...