CDM-625 Advanced Satellite Modem
Revision 1
Preface
MN-0000036 (Ref MN/CDM625.IOM)
Electrical Safety
The CDM-625 has been shown to comply with the
EN 60950 Safety of Information
Technology Equipment (including electrical business machines)
safety standard.
The equipment is rated for operation over the range 100 - 240 volts AC, or, appropriately
equipped, 36 – 60 volts DC. It has a maximum power consumption of 300 watts.
IMPORTANT
The user should observe the following instructions:
Fuses
The CDM-625 is fitted with two fuses – one each for line and neutral connections. These are
contained within the body of the IEC power inlet connector, behind a small plastic flap.
•
For 230/115 volt AC operation, use T4A, 20mm fuses.
•
For 48 volt DC operation, use T8A fuses, 20mm fuses.
CAUTION
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
Environmental
The CDM-625 must not be operated in an environment where the unit is exposed to extremes of
temperature outside the ambient range 0 to 50°C, precipitation, condensation, or humid
atmospheres above 95% RH, altitudes (un-pressurised) greater than 2000 metres, excessive dust
or vibration, flammable gases, corrosive or explosive atmospheres.
Operation in vehicles or other transportable installations that are equipped to provide a stable
environment is permitted. If such vehicles do not provide a stable environment, safety of the
equipment to EN60950 may not be guaranteed.
Installation
The installation and connection to the line supply must be made in compliance to local or national
wiring codes and regulations.
The CDM-625 is designed for connection to a power system that has separate ground, line and
neutral conductors. The equipment is not designed for connection to power system that has no
direct connection to ground.
The CDM-625 is shipped with a line inlet cable suitable for use in the country of operation. If it is
necessary to replace this cable, ensure the replacement has an equivalent specification. Examples
xix
Содержание CDM-625
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 26: ...CDM 625 Advanced Satellite Modem Revision 1 Preface MN 0000036 Ref MN CDM625 IOM xxiv Notes...
Страница 48: ...CDM 625 Advanced Satellite Modem Revision 1 Introduction MN 0000036 Ref MN CDM625 IOM 1 22 Notes...
Страница 148: ...CDM 625 Advanced Satellite Modem Revision 1 Front Panel Operation MN 0000036 Ref MN CDM625 IOM 5 76 Notes...
Страница 182: ...CDM 625 Advanced Satellite Modem Revision 1 Ethernet Management MN 0000036 Ref MN CDM625 IOM 6 34 Notes...
Страница 206: ...CDM 625 Advanced Satellite Modem Revision 1 Forward Error Correction Options MN 0000036 Ref MN CDM625 IOM 7 24 Notes...
Страница 240: ...CDM 625 Advanced Satellite Modem Revision 1 EDMAC Channel MN 0000036 Ref MN CDM625 IOM 11 4 Notes...
Страница 244: ...CDM 625 Advanced Satellite Modem Revision 1 Offset QPSK Operation MN 0000036 Ref MN CDM625 IOM 13 2 Notes...
Страница 258: ...CDM 625 Advanced Satellite Modem Revision 1 Eb No Measurement MN 0000036 Ref MN CDM625 IOM B 4 Notes...
Страница 320: ...CDM 625 Advanced Satellite Modem Revision 1 Remote Control MN 0000036 Ref MN CDM625 IOM D 60 Notes...
Страница 322: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...