11-16
Diagnostic Tools
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1786-Drive Array
Recovery Needed
The following drive(s)
need Automatic Data
Recovery: Drive
X
.
Select "F1" to
continue with
recovery of data to
drive(s). Select "F2"
to continue without
recovery of data to
drive(s).
None
Interim Data Recovery
mode. Data has not been
recovered yet.
Press F1 key to allow
Automatic Data
Recovery to begin.
Data will automatically
be restored to drive
X
now that the drive has
been replaced or now
seems to be working.
-Or-
Press the F2 key and
the system will
continue to operate in
the Interim Data
Recovery mode.
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive
X
None
Hard drive
X
failed or
cable is loose or defective.
Following a system restart,
this message reminds you
that drive
X
is defective
and fault tolerance is
being used.
Replace drive
X
as
soon as possible.
A loose or defective
cable also may cause
this error.
* L= Long
S = Short
continued