Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1761-Fixed Disk 1
does not support
Block Mode
None
Fixed disk drive error.
Run the System
Configuration Utility
and correct.
1764- Slot x Drive Array - Capacity Expansion Process is
Temporarily Disabled (followed by one of the following):
Expansion will resume when Array Accelerator has been
reattached.
Expansion will resume when Array Accelerator has been
replaced.
Expansion will resume when Array Accelerator RAM allocation is
successful.
Expansion will resume when Array Accelerator battery reaches
full charge.
Expansion will resume when automatic data recovery has been
completed.
Reattach or replace
Array Accelerator, wait
until the Array
Accelerator batteries
have charged, or for
Automatic Data
Recovery to complete,
as indicated.
1765-Slot x Drive Array Option ROM Appears to Conflict With an
ISA Card. ISA cards with 16-bit memory cannot be configured in
memory range C0000 to DFFFF along with the SMART-2/E 8-bit
Option ROM due to EISA bus limitations. Please remove or
reconfigure your ISA card.
Remove or reconfigure
conflicting ISA cards.
Disable "shared
memory" on any ISA
network cards that
may be installed. Call
customer support if
this does not help.
* L= Long
S = Short
continued