11-45
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
DAAD Diagnostic Messages
Continued
Error Messages
Possible Corrective Action
LOGICAL DRIVE X STATUS
= FAILED
This status could be issued for several reasons. If this logical
drive is configured for No Fault Tolerance and one or more
drives fail, this status will occur. If mirroring is enabled, and
any two mirrored drives fail, this status will occur. If Data
Guarding is enabled, and two or more drives fail in this unit,
this status will occur. This status may also occur if another
configured logical drive is in the WRONG DRIVE REPLACED or
LOOSE CABLE DETECTED state. Check for drive failures,
wrong drive replaced, or loose cable messages. If there was a
drive failure, replace the failed drive(s) and then restore the
data for this logical drive from the tape backup. Otherwise,
follow the wrong drive replaced or loose cable detected
procedures.
LOGICAL DRIVE X STATUS
= INTERIM RECOVERY
A physical drive in this logical drive has failed. The logical
drive is operating in interim recovery mode and is vulnerable.
Replace the failed drive as soon as possible.
LOGICAL DRIVE X STATUS
= LOOSE CABLE DETECTED
A physical drive has a cabling problem. Turn the system off
and attempt to reattach the cable onto the drive. If this does
not work, replace the cable.
LOGICAL DRIVE X STATUS
= NEEDS RECOVER
A physical drive failure in this logical drive has failed and has
now been replaced. This drive needs to be rebuilt from the
mirror drive or the parity data. When booting up the system,
select the "F1 - rebuild drive" option to rebuild the replaced
drive.
LOGICAL DRIVE X STATUS
= OVERHEATED
The temperature of the Intelligent Array Expansion System
drives is beyond safe operating levels and it has shut down to
avoid damage. Check the fans and the operating
environment.
LOGICAL DRIVE X STATUS
= OVERHEATING
The temperature of the Intelligent Array Expansion System
drives is beyond safe operating levels. Check the fans and the
operating environment.
LOGICAL DRIVE X STATUS
= RECOVERING
A physical drive in this logical drive has failed and has now
been replaced. The replaced drive is rebuilding from the
mirror drive or the parity data. Nothing needs to be done.
Normal operations can occur.