10-2
Server Management
Writer: Project: Server Management Comments:
File Name: N-ch10.doc Last Saved On: 4/23/96 11:31 AM
Level II Temperature,
Immediate Shutdown
When temperatures exceed the factory preset level II temperature threshold,
the hardware tracking of the system thermal environment executes an
immediate power supply shutdown. This shutdown decreases the potential for
heat-related damage to the system components.
Power Supply Tracking
If an optional redundant power supply is installed, an alert is generated in the
event of partial power supply failure. Contact your Compaq Authorized
Service Provider promptly to arrange replacement.
AC Power Failure - Auto Shutdown
You can configure your server to start an automatic operating system
shutdown when the AC power is out and the Compaq UPS battery storage
time falls below a setting that you establish. This shutdown allows for proper
clean-up of operating system files, reducing server downtime if AC power
does not return before battery depletion. Use Insight Manager or the Compaq
System Configuration Utility to set this option.
Storage Subsystem Thermal Tracking
The hardware tracking of the storage chassis thermal environment provides an
alert to the Insight Manager console when the storage subsystem temperature
exceeds the factory preset temperature threshold.
Battery Failure Tracking
The hardware has the ability to notify you of a failing real-time clock battery
before a failure actually occurs. This will enable you to replace the battery at
a scheduled maintenance check and ensure you don't lose valuable non-
volatile RAM information.