Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
605-Diskette Drive
Type Error
2S
Mismatch in drive type
Run the System
Configuration Utility to
set diskette type
correctly.
702-A coprocessor
has been detected
that was not reported
by CMOS.
None
Installed coprocessor not
configured.
Run the System
Configuration Utility
and correct.
703-CMOS reports a
coprocessor that has
not been detected
2S
Coprocessor or
configuration error.
Run the System
Configuration Utility
and correct
1151-Com Port 1
Address Assignment
Conflict
2S
Both external and internal
serial ports are assigned
to COM1.
Run the System
Configuration Utility
and correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2S
Both external and internal
serial ports are assigned
to COM2, COM3 or COM4.
Run the System
Configuration Utility
and correct.
1600-Server
Manager/R Failure
None
Server Manager/R board
failure. Error code displays
after error message.
Run Diagnostics.
Contact your service
provider
1613-Low System
Battery
None
Real time clock system
battery is running low on
power.
Run Diagnostics.
Contact your service
provider.
1610-Temperature
violation detected.
Waiting for system to
cool
2S
Ambient system
temperature too hot.
Check fan in system
environment.
1611-Fan failure
detected
2S
Required fan not installed
or spinning.
Check fans.
* L= Long
S = Short
continued