10-7
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Server Management Comments:
File Name: N-ch10.doc Last Saved On: 4/23/96 11:31 AM
Table 10-1
Critical Error Log Error Messages
Error Message
Description
Automatic Server Recovery
Base Memory Parity Error
The system detected a data error in base memory
following a reset due to the Automatic Server
Recovery (ASR-2) Timer expiration.
Automatic Server Recovery
Extended Memory Parity Error
The system detected a data error in extended
memory following a reset due to the ASR-2 Timer
expiration.
Automatic Server Recovery
Memory Parity Error
The system ROM was unable to allocate enough
memory to create a stack. Then, it was unable to put
a message on the screen or continue booting the
server.
Automatic Server Recovery Reset
Limit Reached
The maximum number of system resets due to the
ASR-2 timer expiration has been reached, resulting in
the loading of Compaq Utilities.
Error Detected On Boot Up
The server detected an error during the Power-On
Self-Test.
Diagnostic Error
An error was detected by the Diagnostics utility.
Refer to the specific error code in this chapter for a
detailed explanation.
NMI - PCI Bus Parity Error
A parity error was detected on the PCI bus.
NMI - Expansion Board Error
A board on the expansion bus indicated an error
condition, resulting in a server failure.
NMI - Expansion Bus Master
Time-Out
A bus master type expansion board in the indicated
slot did not release the bus after its maximum time,
resulting in a server failure.