. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11-47
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
DAAD Diagnostic Messages
Continued
Error Messages
Possible Corrective Action
LOGICAL DRIVE X STATUS
= WRONG DRIVE
REPLACED
A physical drive in this logical drive has failed. The incorrect
drive was replaced. Replace the drive that was incorrectly
replaced. Then, replace the original drive that failed with a
new drive. Do not run the System Configuration Utility to
reconfigure - you will lose data on the drive.
MIRROR DATA
MISCOMPARE
Data was found at reinitialization in the posted write memory,
however, the mirror data compare test failed resulting in data
being marked as invalid. Data loss is possible. Replace the
array accelerator board.
MIRRORED MEMORY
LOCATION ERRORS
Soft errors occurred when attempting to read the same data
from both sides of the mirrored memory errors. Data loss will
occur. Replace the array accelerator board.
NO CONFIGURATION FOR
ACCELERATOR BOARD
The array accelerator board has not been configured. If the
array accelerator board is present, run the System
Configuration Utility to configure the board.
PHYSICAL DRIVE (BAY) X
ERROR OCCURRED
This message displays detailed information on any drive
errors that were returned to DAAD while issuing drive
commands. Check for other error conditions.
PHYSICAL DRIVE (BAY) X
HAS LOOSE CABLE
The array controller could not communicate with this drive at
power-up. This drive has not previously failed. Check all cable
connections first. The cables could be bad, loose, or
disconnected. Turn on the system and attempt to reconnect
data/power cable to the drive. If this does not work, replace
the cable. If that does not work, the drive may need to be
replaced.
PHYSICAL DRIVE (BAY) X IS
A REPLACEMENT DRIVE
This drive has been replaced. This message displays if a drive
is replaced in a fault tolerant logical volume. If the
replacement was intentional, allow the drive to rebuild.
PHYSICAL DRIVE (BAY) X IS
A REPLACEMENT DRIVE
MARKED OK
This drive has been replaced and marked OK by the firmware.
This may occur if a drive has an intermittent failure (for
example, if a drive has previously failed, then when DAAD is
run, the drive starts working again). Replace the drive.
continued