11-31
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
6500 Series -
SCSI Fixed Disk Drive Test Error Codes
The 6500 series of Diagnostic error codes identify failures with fixed disk
drives, fixed disk drive controller boards, fixed disk drive cabling, and system
board functions. Corrective action may require replacement of fixed disk drive
cables, fixed disk drive controller, fixed disk, or system board assembly. If
your system uses a drive array controller, see the section for Drive Array
Advanced Diagnostics (DAAD).
SCSI Fixed Disk Drive Test Error Codes
Error Code Range
Possible Corrective Action
6500-xx ... 6528-xx Loose or defective cable connections may cause error messages. The
fixed disk drive, the fixed disk drive controller, or the system board may
require replacement.
6600 Series -
CD-ROM Drive Test Error Codes
The 6600 series of Diagnostic error codes identify failures with the CD-ROM
cabling, CD-ROM drive, adapter board, or system board assembly. Corrective
action may require replacement of the CD-ROM cabling, CD-ROM drive,
adapter board, or system board assembly.
CD-ROM Drive Test Error Codes
Error Code Range
Possible Corrective Action
6600-xx ... 6628-xx A defective CD, loose cable connections, or defective cable connections
may cause error messages. The CD-ROM drive, the CD-ROM adapter