9 System Options
CommPact Installation Manual
60
9.14. Report Fail Trouble
If the Report Fail Trouble option is enabled, failure to report an event displays System Trouble on the
LCD display. Report Fail Trouble is displayed after the Control System has exhausted all message
attempts and report cycles when trying to report the event. To restore a System Trouble condition
caused by failure to report, press
until you have scrolled through the entire system trouble list. If the
Report Fail Trouble is disabled, failure to report an event does not cause a system trouble condition.
To program the Report Fail Trouble option:
1.
From the Programming menu, select System Options, Rep. Fail Trb. [9416].
2.
Select Enabled or Disabled.
9.15. Immediate Setting from WUApp
If immediate setting from WUApp is enabled, all WEB Set commands received are executed
immediately regardless of the programmed Exit Delay – see p. 49
8.1 Entry/Exit Delay. If disabled,
the SET commands will be executed with the programmed Exit Delay.
1.
From the Programming menu, select System Options, WEB Immed. Set [9417].
2.
Select Enabled or Disabled.
Содержание Control system
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...