4 Advanced System Operation
CommPact Installation Manual
32
4.7.10. RF RSSI level
You can measure the RF RSSI level (RF noise measured by the systems' receiver) using the system’s
RSSI (Received Signal Strength Indication) meter. The Control System will start measuring the RSSI
level of the receiver every second, and it will display the result in levels from 1 to 9 – similar to the
level of detector transmitter's signal strength. It is recommended that the gap between the RF noise
level and the TX signal strength be at least 2. For example, if the RF RSSI level is 5 and the TX signal
strength is 6, consider relocation of the Control System or its peripherals – see p. 7
2.1.1 Wireless
Installation Guidelines.
The menu will have timeout of 5 minutes. If the engineer doesn't exit the menu within 5 minutes of
its entry, the Control System will exit all menus.
To view the RF RSSI level reading:
•
From the Service menu, select RF & GSM level, RF RSSI level [7092]; the RF RSSI level
of the Control System's receiver is displayed.
4.7.11. Display
Version
To display the system’s software and hardware versions:
•
From the Service menu, select Version [710]; the software (SW) versions is displayed.
4.7.12. Enable
Programming
The Enable Programming command enables a user with Master code authorization to grant access
to system programming. This feature is relevant only if the Engineer Access and/or the RP Access
options are programmed as "User Initiated" – see p. 59,
9.11 and p. 66, RP Access Options.
To grant access to the engineer or Remote Programmer:
•
From the Service menu, select Enable Prog. [711]; a 30-minute time window is opened
during which the Engineer Code is valid or RP communication may be established.
Содержание Control system
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...