9 System Options
CommPact Installation Manual
54
If activating the detector does not help, there may be a problem with the detector. You can omit the
faulty detector’s zone to allow system setting until the problem is remedied – see p. 24,
4.3 Zone
Omitting.
Zone omitting is valid for one setting period only. All omitted zones are automatically
un-omitted when the system is unset.
To program the Supervised Set interval:
1.
From the Programming menu, select System Options and Set/Unset, Superv. Set [94023].
2.
Enter a Supervised Set interval (001-255 minutes or 000 to disable the Supervised Set
option).
Do not program a Supervised Set interval that is less than the detector’s supervision
time
9.2.4. Instant
Setting
Instant setting is a feature that allows you to cancel the entry delay after setting the system – see p.
21,
3.7.2 Instant . The feature is designed for use in situations where the system’s perimeter is set
and nobody is expected to enter the premises from outside during the set period.
To enable/disable the Instant Set option:
1.
From the Programming menu, select System Options, Set/Unset, and Instant Setting
[94024].
2.
Select Enabled or Disabled.
9.2.5. Keyfob
Unset
The Keyfob Unset option enables you to determine whether it is possible for the user to unset the
system using their keyfob at all times or during the entry delay only.
This feature can be applied only after the system has been fully set.
1.
From the Programming menu, select System Options, Set/Unset and KF Unset [94025].
2.
Select Always or On Entry.
9.2.6.
Supervised Set Mode
For the Supervised Set option, you can choose whether the Control System waits for a transmission
of all the devices included in this supervision, or from at least one of them – see p. 53,
9.2.3
Supervised .
To program the Supervised Set mode:
1.
From the Programming menu, select System Options, Set/Unset, and Super Set Mode
[94026].
2.
Select All Reg. Devices or Any Reg. Devices.
9.3. Panic
Alarm
SOS Panic alarms generated from the front panel, keypads or keyfobs can be defined as either
audible or silent.
To program the Panic Alarm setting:
1.
From the Programming menu, select System Options, Panic Alarm [9403].
2.
Select Audible or Silent.
Содержание Control system
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...