3 Basic System Operation
CommPact Installation Manual
17
Item
Description
PART SETTING INST
The system is in the process of setting with the Instant set feature activated.
PERIM SETTING INST
Table 3-5: System Status
Item
Description
ZONES IN ALARM
Zones have been violated.
TAMPER ALARM
The system has been tampered with.
56 TO EXIT
The exit delay is counting down (56 seconds remaining).
11 TO UNSET
The entry delay is counting down (11 seconds remaining).
SYSTEM NOT READY
The system is not ready to set, check that all doors and windows are closed.
KEYPAD LOCKED
Five unsuccessful attempts were made to enter a user code; the keypad is locked for
30 minutes.
SYSTEM TROUBLE
A trouble condition has been detected, press
for further details.
3.5. Audible
Notification
The following table is a summary of tones that audibly notify system status.
Table 3-6: Audible Notification
Status
Tones
Description
Positive
Acknowledge
1 long tone.
The preceding action was accepted.
Negative
Acknowledge
5 low tones.
The preceding action was not accepted (e.g. an
incorrect user code entry).
Exit Delay/
Entry Delay
External Sounder: 4 tones.
Built-in Sounder: 4 tones or
Continuous tones.
Continuous tones quicken
when there are 15 seconds
remaining and quicken
again when there are 5
seconds remaining.
The exit/entry delay is counting down.
The number of tones sounded during each delay is
determined in programming – see
The number of tones sounded during each delay is – see
p. 50 8.5 Setting Tones.
Chime
2-tone modulated sequence
(similar to a doorbell).
A zone with the Chime option enabled has been opened
– see p. 43 7.3.5 Chime .
Set
3-tone modulated sequence
(low to high) sounded twice
The system has been set using any of the setting
methods.
Unset
3-tone modulated sequence
(high to low).
The system has been unset.
System Trouble
4 rapid tones sounded once
per minute.
A trouble condition has been detected, press
for further
details. For Fire Trouble Tones, there is a programmable
option to repeat fire-related trouble tones until the problem
has been taken care of – see p. 51, 8.6.3 Fire Trouble
Tones.
3.5.1.
System Trouble Tones
In the event of system trouble, the CommPact Control System sounds a series of tones to alert the
user. To silence these tones, press
and scroll through the system trouble list displayed on the
LCD. When the trouble condition is restored, it is removed from the system trouble list.
Содержание Control system
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...