Appendix B: Transmitter Installation
CommPact Installation Manual
135
2.
Press '
√ʹ;
New Device
appears on the display.
3.
Press '
√ʹ again;
Transmit 1
appears on the display.
4.
Send two transmissions from the device you want to register.
5.
When the transmitter number and
Save?
appears on the display, press '√' to confirm
registration.
The EL-2635 repeater automatically allocates a transmitter number to each newly registered
device. Write this number and the zone number on the sticker provided with the detector
and stick it inside the transmitter's cover for future reference.
6.
After you have confirmed registration, the display returns to New Device. Press '
√ʹ to
register another device or press Χ to exit Registration mode.
Deleting Registered Transmitters
To delete transmitters from the repeater’s registry:
1.
On the LCD programming keypad, press
until
3. TX Delete
appears on the display.
2.
Press '
√ʹ; the first transmi$er in the list appears on the display.
3.
Use the arrow navigation keys (5/6) to scroll to the transmitter you want to delete.
4.
Press '
√ʹ to select the transmi$er.
5.
Press '
√ʹ
again for confirmation; the transmitter is deleted.
6.
Select another transmitter to delete or press Χ to exit.
Engineer Utilities
The EL-2635 repeater offers two engineer utilities that serve as a valuable aid during installation
and maintenance.
TX List
The TX List is a scrollable inventory of all transmitters that are registered to the repeater and their
last reported signal strength.
To view the TX list:
1.
Press
until 1.
TX List
appears on the display.
2.
Press '
√ʹ; the first transmi$er in the list
is displayed.
3.
Use the arrow navigation keys (
/
) to scroll through the list.
4.
Press Χ to exit the list.
TX Test:
TX Test is a utility that enables you to identify transmitters that are registered to the repeater and to
test their signal strength.
To perform the TX test:
1.
Press
until
2. TX Test
appears on the display.
2.
Press '
√ʹ.
3.
Activate a transmitter; the transmitter number, type and signal strength are displayed.
4.
Press Χ to exit TX Test mode.
Содержание Control system
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...