T-Series Traffic Director Installation, Configuration and Administration Guide
2-3
Cautions and Warnings
•
Do not work alone when working with high voltage components.
•
Always disconnect the T1000 from power before removing or installing any
component. When disconnecting power, you should first shut down the T1000 and
then unplug the power cords of all the power supply units connected to the T1000.
As long as the power cord is plugged in, line voltages may be present in the power
supply, even when the power switch is OFF.
•
Do not use mats designed to decrease static electrical discharge as protection from
electrical shock. Instead, use rubber mats that have been specifically designed as
electrical insulators.
•
Make sure that the power source can handle the T1000's maximum power
consumption rating with no danger of an overload. Always unplug any T1000 before
performing repairs or upgrades.
•
Do not overload the wiring in your server cabinet or on your server room rack.
•
During thunderstorms, or anticipated thunderstorms, avoid performing any hardware
repairs or upgrades until the danger of lightning has passed.
•
When you dispose of an old T1000 or any components, follow any local and national
laws on disposal of electronic waste.
•
To prevent possible explosions, replace expired batteries with the same model or a
manufacturer-recommended substitute and follow the manufacturer’s instructions on
battery replacement.
•
Never remove a power supply cover or any sealed part that has the following label:
T1000 Precautions
•
Determine the placement of each component in the rack before you install the rail.
•
Install the heaviest component first at the bottom of the rack, and then work upward.
Distribute the load on the rack evenly. An unbalanced rack is hazardous.
•
Allow the power supply units to cool before touching them.
•
Install the equipment near a socket outlet for easy access.
•
Mount equipment into a rack with sufficient airflow for safe operation.
•
For a closed or multi-unit rack assembly, the ambient operating temperature of the
rack environment may be greater than the ambient temperature of the room.
Therefore, consider the lowest and highest operating temperatures of the equipment
when making a decision about where to install the T1000 in the rack.
Содержание ByteMobile T1010
Страница 10: ...x T Series Traffic Director Installation Configuration and Administration Guide...
Страница 14: ...Contents xiv T Series Traffic Director Installation Configuration and Administration Guide...
Страница 150: ...B 10 T Series Traffic Director Installation Configuration and Administration Guide Appendix B Replacement Parts...
Страница 168: ...Glossary Glossary 12 T Series Traffic Director Installation Configuration and Administration Guide...
Страница 172: ...Index Index 4 T Series Traffic Director Installation Configuration and Administration Guide...