IP Dual Port PBXgateway and Remote System Administrator’s Guide
98
4. Assuming that the file is present at the “ftp” prompt type:
a) get xxx.xxx.xxx.xxx yyy zzz <path> <new file>, where:
à
xxx.xxx.xxx.xxx is the IP address of the ftp server
à
yyy zzz is the login user and password for the ftp server
à
<path> is the full path to the image file including the file name
à
<new file> is the name that the file is to be given on the flash file system
For example, get 102.168.2.22 user1 pswd1 c:\EXTender\update\3.61.5r1.mab
3.61.5r2.mab
5. Press Enter to download the image file to the unit. The file transfer begins and the
transfer status is indicated by a stream of dots across the screen. The transfer should
take approximately 15 minutes.
6. When file transfer is complete and the “ftp” prompt is displayed, press ESC to exit the
FTP Shell.
7. The new image file has been uploaded. You may now copy the image to other units if
required – see the “Via In-Band Upload” section.
8. The image may now be copied to multiple units if required. See the
Via In-Band
Upload
section for details.
9. The unit is now ready to upgrade to the new software image. See the
File Upgrade
section for details.