IP Dual Port PBXgateway and Remote System Administrator’s Guide
31
Advanced Configuration – Quick Reference
This section is a quick reference list of the additional configuration steps that can be
performed either during the execution of the Setup Wizard or anytime after to improve
system performance. Although not required, the advanced features may be used to assist
with managing the units or trouble shooting voice issues. Please consult the Advanced
Configuration section prior to contacting customer support. A full description of the
features described below begins with the
Advanced Configuration – PBXgateway
section.
1. Identify the port by entering a Description for the specific port (typically user’s name).
Path:
Gateway (and Remote) ->Configuration->Port->Port_1 (and Port_2)
►
Refer to page
45
and page
52
for full details.
2. Setup a Connect password to provide a secure connection restricting unauthorized
access to the PBXgateway port from the Remote.
Path:
Gateway (and Remote) ->Configuration->Port->Port_1 (and Port_2)
►
Refer to page
45
and page
52
for full details.
3. Set Auto-connect to “enabled” for the sets to automatically connect to the
PBXgateway. If the connection to the PBXgateway is lost for any reason the sets will
attempt to automatically re-connect.
Path:
Remote->Configuration->Port->Port_1 (and Port_2)
►
Refer to page
52
for full details.
4. The Diversion parameter (Ericsson PBX only) is used to enable the PBX feature of
forwarding of all calls when the user disconnects from the PBXgateway.
Path:
Remote->Configuration->Port->Port_1 (and Port_2)
►
Refer to page
52
for full details.
The Diversion parameter will only be presented if Ericsson is selected as the PBX type.
For a full description of this feature refer to the Ericsson PBX documentation.
5. Enable Active Call Monitoring (Nortel Norstar PBX only) to monitor another station’s
activity (on another call, for example).
Path:
Remote->Configuration->Port->Port_1 (and Port_2)->Phone_Features
►
Refer to page
52
or full details
.
6. Configure Line Signaling (Nortel Norstar PBX only) – Used to help eliminate clicking
noise in the audio path on certain installation environments.
Path:
Gateway (and Remote) ->Configuration->Port->Port_1 (and Port_2)
►
Refer to page
45
and page
52
or full details.
7. Provide a system name making it easier to identify the unit when administering
multiple PBXgateways or multiple Remotes.
Path:
Gateway (and Remote) ->Configuration->System
►
Refer to page
46
and page
56
for full details.
8. Set the Time and Date to provide accurate time and date stamps for trouble shooting
and system maintenance.
Path:
Gateway (and Remote) ->Utilities->System->Set Date
►
Refer to page
47
and page
57
full details.
Document Number: M-4100-MUC
Version: Rev AA
© Copyright 2007 Citel plc All Rights Reserved