IP Dual Port PBXgateway and Remote System Administrator’s Guide
20
Do NOT connect the PBXgateway to the PBX or connect the digital telephone(s) to
the Remote until the Setup Wizard has been run. An improperly configured
PBXgateway can cause damage to the PBX line card and an improperly configured
Remote can cause damage to the digital telephone sets.
!
6. Wait a few seconds and the “Press 'Enter' to start the shell...” prompt is displayed.
7. Press
Enter. A password prompt if a displayed if a password is set (there is no default
password).
If the PBXgateway or Remote software is running but you do not see these prompts, the
serial connection between your computer and the units may be at fault. You must correct
this problem before you can use the HyperTerminal connection successfully. See
Direct
Serial Connection
on the previous page.
8. Type the unit’s password, if one is set, and press Enter.
The Console UI welcome screen is displayed (see
Figure 3
below)
9. To be sure that you can see all the information displayed, you must set the screen
size to 24 lines x 80 columns.
The screen size is correctly set when the Welcome screen is displayed with the #
border, as shown in
Figure 3
.
Figure 3: The PBXgateway Console UI – Welcome Screen
Using your mouse, click, hold and drag the corner of the screen until you can see the
#
border, then release your mouse button.
The Welcome Screen for the Remote is the same except it will display “Citel
Technologies, IP Dual Port (or Single Port) Remote”
Document Number: M-4100-MUC
Version: Rev AA
© Copyright 2007 Citel plc All Rights Reserved